By incorporating a novedesign of 561nm all-solid-state laser and violet side-angle scattering channel (VSSC), FongCyte™ S enables to supporting fine analysis of up to 14 colors or detection small particles with 13 colors.
By incorporating a novedesign of 561nm all-solid-state laser and violet side-angle scattering channel (VSSC), FongCyte™ S enables to supporting fine analysis of up to 14 colors or detection small particles with 13 colors.
Superior Performance
Unlimited Potential
Vssc: Unlock A New Micro-World of 80 nm Size with Nanoscale Precision
The violet side scatter channel (VSSC) significantly enhances the resolution capability for micro-particles, such as bacteria, viruses, nanoscale drug carriers, and extracellular vesicles (EV) :
The integration of VSSC enables simultaneous analysis of heterogeneous populations with micro-particle sizes from 80nm to 1.3μm;
VSSC not only enables to distinguish the size of nanoparticles, but also precisely identify the differences in microsphere materials through scattered light changes.
561nm Laser: Outstanding Red Fluorescence Detection Performance
The 561nm laser is the best excitation light for mCherry and other red fluorescent proteins;
The excitation efficiency of PE family dyes is increased by over 40% ;
It can simplify operation by reducing the overlap between FITC and fluorescent dyes of PE family for eliminating fluerescence compensation regulation;
8-peak detection results of SPHERO™ rainbow beads, demonstrates excellent instrument sensitivity:
Patented Laser Stabilization Design, Significantly enhancing performance:
All channel Stain Index (SI) have been improved, and weak expression markers and low content cells can be clearly distinguished.
Intelligent and Efficient Throughout, User-Friendly, and Highly Accurate Detection:
01 Sample Preparation:
02 Startup:
One-click quick startup instant stable ues:
● The process of stability only requires 7minutes without the need for warm-up, saving time;
● Can ensure stable laser performance and prolong laser lifespan.
03 Measurement:
Real-time monitoring, smart troubleshooting:
● Intelligent monitoring, automatically resolving anomalies without manual processing;
● Intelligent anti-collision design of sampling needle ensure safe use and smooth detection.
Multiple patented designs ensure accurate and reliable detection results:
● Unique precise temperature control system of laser and detecor;
● Integrated locking optical path;
● 3Dring filters;
● Independent fibler conduction.
04 Analysis:
Intelligent analysis software-ModelFlower
● Bilingual display in Chinese and English, graphical tools and wizard;
● Audit trail for electronic signatures: meeting the requirements of 21 CFR part 11;
● Automatic identification cell position and gating, eliminating the need for complicated adjustments and simplifying analysis;
● Built-in common analysis modules for scientific research;
● The overlay function can use scatter plots or histograms to display various data analysis;
● Support LIS statistics and graphic sharing function;
● One-touch automatic QC to monitor the resolution of each fluorescent channel and the stability of median fluorescence intensity(MFI);
● Levey-Jennings graph tracks and monitors instrument performance.
05 Shutdown:
Smart maintenance, automatic shutdown:
No waiting or supervision time required, once detection is completed, the system will automatically proceed to cleaning, shutdown, and power-off, requiring no human assistance.
Configuration:
Superior Performance
Unlimited Potential
Vssc: Unlock A New Micro-World of 80 nm Size with Nanoscale Precision
The violet side scatter channel (VSSC) significantly enhances the resolution capability for micro-particles, such as bacteria, viruses, nanoscale drug carriers, and extracellular vesicles (EV) :
The integration of VSSC enables simultaneous analysis of heterogeneous populations with micro-particle sizes from 80nm to 1.3μm;
VSSC not only enables to distinguish the size of nanoparticles, but also precisely identify the differences in microsphere materials through scattered light changes.
561nm Laser: Outstanding Red Fluorescence Detection Performance
The 561nm laser is the best excitation light for mCherry and other red fluorescent proteins;
The excitation efficiency of PE family dyes is increased by over 40% ;
It can simplify operation by reducing the overlap between FITC and fluorescent dyes of PE family for eliminating fluerescence compensation regulation;
8-peak detection results of SPHERO™ rainbow beads, demonstrates excellent instrument sensitivity:
Patented Laser Stabilization Design, Significantly enhancing performance:
All channel Stain Index (SI) have been improved, and weak expression markers and low content cells can be clearly distinguished.
Intelligent and Efficient Throughout, User-Friendly, and Highly Accurate Detection:
01 Sample Preparation:
02 Startup:
One-click quick startup instant stable ues:
● The process of stability only requires 7minutes without the need for warm-up, saving time;
● Can ensure stable laser performance and prolong laser lifespan.
03 Measurement:
Real-time monitoring, smart troubleshooting:
● Intelligent monitoring, automatically resolving anomalies without manual processing;
● Intelligent anti-collision design of sampling needle ensure safe use and smooth detection.
Multiple patented designs ensure accurate and reliable detection results:
● Unique precise temperature control system of laser and detecor;
● Integrated locking optical path;
● 3Dring filters;
● Independent fibler conduction.
04 Analysis:
Intelligent analysis software-ModelFlower
● Bilingual display in Chinese and English, graphical tools and wizard;
● Audit trail for electronic signatures: meeting the requirements of 21 CFR part 11;
● Automatic identification cell position and gating, eliminating the need for complicated adjustments and simplifying analysis;
● Built-in common analysis modules for scientific research;
● The overlay function can use scatter plots or histograms to display various data analysis;
● Support LIS statistics and graphic sharing function;
● One-touch automatic QC to monitor the resolution of each fluorescent channel and the stability of median fluorescence intensity(MFI);
● Levey-Jennings graph tracks and monitors instrument performance.
05 Shutdown:
Smart maintenance, automatic shutdown:
No waiting or supervision time required, once detection is completed, the system will automatically proceed to cleaning, shutdown, and power-off, requiring no human assistance.
Configuration: